SUBLANCE FOR MEASUREMENT OF THE SMELTING PARAMETERS (for the converter of 300t)
Purpose:
The sublance for measurement of the smelting parameters is intended for:
- dipping of the probe in the hot metal measurement zone in the converter;
- signal adjustments of the measuring probe sensors and information output to the main operating station of converter;
- lifting of the measurement probe from the converter after sampling of metal;
- removal of the probe from lance and its delivery with metal sample into the sample derivation of the used samples;
- charging the measuring lance with new probes from the working platform;
- performing the heat without tilting of the converter;
- reduction of heat time, ensuring the safe work of personnel.
Specifications:
| Parametrs | Indicators of sublance for measurement of the melting parameters |
| Working stroke of the sublance, m | 18,92 |
| Full stroke of the sublance, m | 19,02 |
|
Lifting-lowering speed of the sublance: Maximum, msec Minimum, msec |
1 0,1 |
| Working travel of the movable platform, m | 11,6 |
| Mobile platform speed, msec | 0,5 |
| The water pressure before the hose, MPa | 1,6 |
| Nitrogen pressure (argon) before the hose, MPa | 0,025 |
| Water consumption, cub.mh | 110 |
| Nitrogen consumption (argon) cub.mmin | 0,0065 |
| Mass, t | 44,56 |